1. Multi ranges
2. Wide application
3. High accuracy, ±0.05% FS.
4. Fast response time.
5. Each channel is independent
6. The side air intake on the left / right side & eight test channels, the inventive heat-radiating system is practical and feasible and can increase heat-radiating efficiency and space utilization rate
Input Power |
AC 220V ±10% / 50Hz |
|
Resolution |
AD:16bit;DA:16bit |
|
Input Resistance |
≥1GΩ |
|
Input Power |
425W |
|
Channel Features |
Constant Current Source and Constant Voltage Source with Independent pairs of Closed-loop Structure |
|
Channel Control Mode |
Independent Control |
|
Voltage |
Per Channel Control Voltage Range |
25mV~5V |
Minimum discharge voltage |
Upper and lower clamp discharge to 1V, 2m cables to 1.5V |
|
Accuracy |
± 0.05% of FS |
|
Stability |
± 0.05% of FS |
|
Current |
Per Channel Current Range |
Rangel 1: 0.5mA~0.1A , Rangel 2: 0.1A~3A, Range 3:3A~6A |
Constant current cut-off current |
Range 1:0.2mA;Range 2:6mA ,Range 3:12mA |
|
Accuracy |
± 0.05% of FS |
|
Stability |
± 0.05% of FS |
|
Power |
Per Channel Output Power |
30W |
Stability |
± 0.1% of FS |
|
Time |
Current Response Time |
<1ms |
Step Time Range |
≤(365*24 )hour/step,Time Form Support 00:00:00.000(h、min、s、MS) |
|
Data Recording |
Record Condition |
Time△t:100ms |
Voltage△U:10mV |
||
Current△I: Range 1:2mA;Range 2:6mA ,Range 3:12mA |
||
Record Frequency |
10Hz |
|
Charge |
Charge Mode |
Constant Current Charge、Constant Voltage Charge、Constant Current and Constant Voltage Charge、Constant Power Charge |
End Condition |
Voltage、Current、Relative Time、Capacity、-△V |
|
Discharge |
Discharge Mode |
Constant Current Discharge、Constant Voltage Discharge、Constant Current and Constant Voltage Discharge、Constant Power Discharge、Constant Resistance Discharge |
End Condition |
Voltage、Current、Relative Time、Capacity、-△V |
|
Pulse Test |
Charge |
Constant Current Charge、Constant Power Charge |
Discharge |
Constant Current Discharge、Constant Power Discharge |
|
Minimum Pulse Width |
500ms |
|
Pulse Number |
32 different pulse for a single step |
|
Charge and Discharge Switch |
continuous switched for a single pulse step |
|
End Condition |
Voltage、Relative Time |
|
DCIR test supported |
||
Cycle |
Loop Measure Range |
1~65535 times |
Max Steps Per Loop |
254 |
|
Nested Loop |
Nested loop Function,Max Support 3 Layers |
|
Protection |
Power-down Data Protection |
|
Off-line Testing Function |
||
Setting Protection Condition, Setting Parameter: Low Voltage limit、Upper Voltage limit、Low Current limit、Upper Current limit、Delay Time 、Anti-reverse Protection Model |
||
Voltage and Current Testing Sample |
4-wire connecting |
|
Noise |
<55dB |
|
Database |
MySQL Database |
|
A Means of Communication of Upper Machine |
TCP/IP Protocol |
|
Data Output |
EXCEL 2003、2010、TXT |
|
Server disk configuration |
500GB |
|
Communication Interface |
Internet Access |
|
Server Operating System |
Windows 7 |
|
Leak current |
<5μA |
|
Per Unit Main Channels No |
8 |
|
Clamp |
Alligator clamp, Polymer clamp, Ring clamp optional |